Address:Shenzhen city Baoan District Xixiang Ping Chau Development Zone No. 90
Post Code: 518000
Tel: +86 (0)769-81738045
FAX: +86(0)769-23225972
Cell Phone: +86 18665111096
Email: Inaral@163.com
相关介绍 |
---|
Information description Type DJY-Z207-3 Measuring conditions Application of grid is not grounded power system, such as DC power grid and rectifier, single-phase and three-phase AC power grid...... Rated voltage Un/AC AC power 0 ~ 1000V AC preferred) The frequency range of 50 ~ 400Hz ('50Hz, please refer to diagram) Rated voltage of Un/DC DC power supply 0 ~ 1000V DC Display range K Omega Omega... Display error ± 5% The response value setting range (ALARM1/ALARM2) 10K ohm to 990K ohm The response value of relative (percentage) error 0%... +20% In response to a difference of about 25% Response time (Ce=1 μ F) ≤ 10 Maximum allowed power capacitor... μ. (factory setting... U. The test voltage of Um (DFB) square wave voltage of ± 27V Test current Lm (DFB μ A).. Internal DC resistance / impedance ZL about 230K Ω /350K In connection with the function of voltage. General data The dielectric strength according to the (IEC255-5) 4000VAC/50Hz Installation position of any Installation standard C35 rail groove (according to IEC 60715 standard) Connection is fixedly connected with the outer terminal by bolts. Display and instructs the LCD liquid crystal display and alarm signal indicatinglamp (LED) Protection level (according to IP 30...) Continuous operation mode The input circuit Input voltage Us 220VAC (AC/110V, 380V please put in order) Working voltage range of 1.15 US 0.8 US... Rated frequency 50/60Hz Frequency range allows the 47.5Hz... 63Hz The rated power of about 5VA The output circuit Show the value of the analog output (max) 1mA Analog output display value accuracy of ± 20% Output contact of 2 relays with changeover contacts, no potential difference (a often open a closed) Contact with rated voltage of 250VAC/30VDC 3A AC/DC continuous load current The maximum operating current of 10A AC/DC Cos 2A AC Environmental conditions Allow the storage temperature of -20 ℃ +70 ℃... Allowed working temperature of -10 ℃ +55 ℃... Climate level allowed (according to IEC60721-3-3) level 3K5 The shape and weight Dimensions (length * width * height) of 112 × 74 × 105mm The weight is about 0.95kg Voltage expander -EX-1800 applicable voltage -0 ~ 1800VAC/0 ~ 1400VDC(applicable to AC, DC and frequency conversion power grid Application of -EX-7200 voltage -0 ~ 7200VAC/0 ~ 1750VDC (for pure AC, DC power system |
Address:Shenzhen city Baoan District Xixiang Ping Chau Development Zone No. 90
Tel: +86 (0)769-81738045 Cell Phone: +86 18665111096 Email: Inaral@163.com Copyright © 2010 - 2015 ShenzhenYingNuoYuanCo.,Ltd All Rights Reserved |